F207 - PCI-104 Carrier Board for 4 PCI-104 COMs
3U CompactPCI
This product has been discontinued.The F207 is a 3U CompactPCI bus card which provides a PCI-104 interface supporting a stack of up to four PCI-104 extension boards.
Main Features
Technical Data
PCI-104
- One slot for PCI-104
- Up to four stacked PCI-104 modules
- 8HP solution with one PCI-104 module mounted
- Second front panel as needed (filler panel or with connector cut-outs)
Peripheral Connections
Via front panel
Local PCI Bus
- 32-bit/33-MHz, 3.3V or 5V (on request) V(I/O)
- Compliant with PCI Specification 2.2
CompactPCI Bus
- Compliance with CompactPCI Core Specification PICMG 2.0 R3.0
- Peripheral slot
- Only one slot required on 3U CompactPCI bus
- PCI2050 PCI-to-PCI bridge
- Max. clock frequency 33MHz
- 32-bit/33-MHz PCI-to-PCI bridge
- V(I/O): +3.3V or +5V (Universal Board)
Electrical Specifications
Supply voltage/power consumption:
- +5V (-3%/+5%), 40mA max. (without PCI-104 module)
- +3.3V (-3%/+5%), 60mA max. (without PCI-104 module)
Mechanical Specifications
- Dimensions: conforming to CompactPCI specification for 3U boards
- Front panel: aluminum with 1 handle
- Weight: 170g
Environmental Specifications
- Temperature range (operation):
- -40..+85°C
- Airflow: min. 10m³/h
- Temperature range (storage): -40..+85°C
- Relative humidity (operation): max. 95% non-condensing
- Relative humidity (storage): max. 95% non-condensing
- Altitude: -300m to + 3,000m
- Shock: 15g/11ms
- Bump: 10g/16ms
- Vibration (sinusoidal): 2g/10..150Hz
MTBF
2,006,823h @ 40°C (derived from MIL-HDBK-217F)
Safety
PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers
EMC
Tested according to EN 55022 (radio disturbance), IEC 61000-4-2 (ESD) and IEC 61000-4-4 (burst)
Software Support
PCI-104 drivers as supported
Options
PCI-104 Slot
- One PCI-104 module mounted "face-to-face" instead of PCI-104 stacking
- 4HP solution with one PCI-104 module mounted (single-slot)
- Only for PCI-104 modules that have a modified or no PCI-104 connector on the bottom side, because of height restriction to 4HP
V(I/O) on Local Bus
5V instead of 3.3V
Cooling Concept
Also available with conduction cooling in MEN CCA frame
Some of these options may only be available for large volumes.
Please ask our sales staff for more information.